Under Ceiling Mounted Evaporative Air Coolers

Registered as No. 37588, dated 20 May 2015 in Iran National Innovations Registering Center

Application Climate

  • Suitable for conditioning weathers such as; hot and dry, hot with low humidity
  • Meets Outdoor Standards, to provide more useful area inside the building. May be installed either beneath any suitable surface like as beneath the terrace ceiling or on a metallic stand.

Note: May be installed indoor (beneath the ceiling of a suitable internal area) provided that a separate fresh air duct with required dimensions is considered in buildings’ supply ducts design.

  • Endurable in heavy environmental conditions such as rain, snow, gust, etc.

Application fields

These products are used especially for cooling of where the energy charges must be handled lonely by individuals, like as:

  • Residential buildings and towers (beneath the ceiling of each units’ terrace, if any)
  • Hotels, motels (beneath the ceiling of each room terrace, if any) and any other small touristic buildings
  • Small restaurants, bars, coffee shops, catering and entertainment saloons which are supported by separate individuals, even though located in same central buildings.   
  • Small industrial and repair shops
  • Many other small public buildings

Technical Features

  • International, National and Factories’ relevant Standards are being considered in design and manufacturing process.
  • High Evaporation Efficiency (92%), Low Energy Consumption, Low noise, Environmental and user Friendly,

     Low Maintenance Costs and designed as an Excellent Outdoor Unit

  • Low Energy Consumption (energy saving, up to %60) respect to ordinary evaporative air coolers with similar

     cooling capacities, because of higher Δt (up to 18 oC in outside air Temp. of 44 oC and RH of %15) which is provided

     by Inverter and LCD Thermostat. In case of compression air conditioners such as Splits, Roof tops and Chillers

     with similar capacities, energy saving will be raised up to %80.

     Note 1: A noticeable reduction in consumed electric power in compare with Splits and Chillers in similar cooling

     capacity (nearly 80% reduction), because of the following reasons:

1-   PFC Inverter (in all capacities)   

2-   High Efficiency Cooling Pads providing necessary cooling demand in Slow up to Medium Fan Speeds (17)

because of high efficiency of cellulose pads. Thus, electric energy consumption will be decreased.

3-   Magnetic Circulating and Drain Pumps which consume lower energy regarding to ordinary water pumps.

4-   Smart Energy Management System (SEMS)

5-   A noticeable reduction in water consumption in compare with other ordinary evaporative air coolers because of excellent cooling media

Note 2: In cellulose pads, evaporation of water is done perfectly because of uniform air speed increase and consequently, uniform pressure drop through cooling media. Generally speaking, decreasing of evaporation pressure for any fluid will cause evaporation rate to increase and consequently fluid consumption will increase. So, if pressure drop can be controlled with respect to air speed through cooling pad, an optimized evaporation may be obtained without waste of water. So as a key point, whatever uniformity and reduction in pressure drop, the lower consumption of water and more comfort without increasing of humidity (more than standard

  • Providing nearly all Air Conditioning Comfort Parameters such as Temperature, Humidity and Air Change per

     Hour (ACH) at Standard Levels, in the Conditioned Medium

  • Providing 100% filtered and humidified (not more than 60% RH) fresh air.

 Note: Our body needs nearly 800 liter/min. of fresh air and also 40% – 50% Humidity. While in other Cooling Procedures such as Compression and Absorption Chillers, nearly 70% of existing air is re-circulated and necessary air shall be supplied by separate Air Handling Units (AHU). In mentioned Cooling Procedures, Fan Coils eliminate existing humidity by condensing, additionally excessive initial investment is required for AHU, Fan Coils and Humidifiers and this issue is not finalized in this step. All of the above mentioned devices are need to service and maintenance. Therefore, related annual charges will increased also. While in Evaporative Cooling Procedure, necessary fresh air and humidity is supplied sufficiently by system and there is no need to other accessory devices.

  • Evaporative Cooling air, through distribution ducts (supply ducts).
  • Direct Drive Fan (DDF), available in all capacities without any pulley, belt and bearings which reduces energy

     consumption, provides very low noise operations and reduces maintenance costs.

  • Cellulose Cooling Pads which cause evaporation efficiency increment up to %92 and provide 5 ◦ C more Δt

     respect to ordinary evaporative air coolers, act as micronic filters to prevent any outside pollutions (such as dust,

     Carbon Particles, micro-organisms and so on) entering to the internal area. At the same time, because of the

     homogenous shape of Cellulose Pads which causes uniform evaporation, water consumption will be decreased also.

  • Internal Elastomeric Thermal Insulation helps to a lower dew point inside the system and permits operation of cooling mode with higher evaporation efficiency.
  • As an outdoor unit, Anodized Aluminum structures, coated by highly resistive coats, provide more endurance against environmental conditions.
  • Low Energy, Anti- jamming, water cooled and lubricated Submersible Magnetic Circulation and Drain Pumps
  • Precisely designed internal water plumbing, provide uniform distribution of water, over Cooling Pads.
  • PFC Inverter (Power Factor Correction feature for fan electric motor) provides Auto Speed Control of fan with respect to temperature set point, via at least 3 up to 17 different RPM.
  • Smart LCD Touch Panel Thermostat, user friendly, Auto and Manual modes, supplied with Remote Control
  • Auto Drain and Washing System (ADWS) permits discharging of whole contaminated water in time interval of 80 hours of system operation and prevents penetration of contaminations inside Cellulose Pads and maintain evaporation efficiency high as well. Prolongs life time of other parts which may be affected adversely by water salts and sediments. The time interval may be customized according to used water hardness.
  • Optimized Energy Consumption, by SEMS (Smart Energy Management System) through Thermostat (remotely

     controlled), Inverter and ADWS. The necessary safety features in SEMS, have been considered.

Note: SEMS provides energy monitoring and saving features, per day or weekly, only in Auto mode. Operation of SEMS needs only to temperature setting and operational time selection. Temperature, Fan Speed and Drain Controls also are available through Manual mode (without SEMS).

  • Maintenance friendly, all service and maintenance operations are done through the beneath of product.

Options

  • SEMS including; LCD Touch Panel Thermostat, Inverter and ADWS.
  • May be ordered either with thermostat and ADWS or thermostat and Inverter configurations (without SEMS).
  • Supplied only in Under The Terrace ceiling Mounted, with 4 different Outlet Positions (according to drawings) with respect to building supply ducts’ positions, to eliminate unnecessary elbows and prevent excessive pressure drops and increasing air supply throughout distribution ducts and easy maintenance operations.